Kameleon Frames 2000T1 and 2000T3 MODELS Instruction Manual 071803902AUGUST 2004
10 Kameleon Frames Instruction ManualRegulatory Notices
Kameleon Frames Instruction Manual 11 Safety Summary Read and follow the important safety information below, noting especially those instructions r
12 Kameleon Frames Instruction ManualSafety Summary Symbols on the Product The following symbols may appear on the product: Warnings The following
Kameleon Frames Instruction Manual 13Safety Summary Use proper power cord — Use only the power cord supplied or specified for this product. Ground
14 Kameleon Frames Instruction ManualSafety Summary Do not operate with suspected equipment failure — If you suspect product damage or equipment f
Kameleon Frames Instruction Manual 15 Section 1 Kameleon 2000 Series Frames Introduction Kameleon 2000T1 and 2000T3 frame models support Kameleon
16 Kameleon Frames Instruction ManualSection 1 — Kameleon 2000 Series Frames Module Slots 2000T3 frame model architecture allows for up to 12 media
Kameleon Frames Instruction Manual 17Module Slots Figure 2. 2000T3 Frame Rear and Interior ViewAn optional redundant power supply (2000PS) can be i
18 Kameleon Frames Instruction ManualSection 1 — Kameleon 2000 Series Frames 2000 Series Frame OptionsA number of options can be ordered for 2000T1 an
Kameleon Frames Instruction Manual 192000 Series Frame Options When the 2000T3 Series frame is loaded with modules that require greater than 150 Watts
2Kameleon Frames Instruction Manual Contacting Grass Valley Copyright © Thomson Broadcast and Media Solutions All rights reserved. Grass Valley Web
20 Kameleon Frames Instruction ManualSection 1 — Kameleon 2000 Series Frames Genlock TimingA 2000GEN Genlock Timing module is available for providing
Kameleon Frames Instruction Manual 212000T3 Frame Connections 2000T3 Frame ConnectionsThe rear of the 2000T3 frame provides twelve rear media or passi
22 Kameleon Frames Instruction ManualSection 1 — Kameleon 2000 Series Frames 2000T1 Frame ConnectionsThe rear of the 2000T1 frame provides four rear m
Kameleon Frames Instruction Manual 23Power, Cooling, and Module Capacity Table 2 provides maximum power usage per module slot for adequate cooling in
24 Kameleon Frames Instruction ManualSection 1 — Kameleon 2000 Series Frames
Kameleon Frames Instruction Manual 25 Section 2InstallationIntroductionThis section contains information about:•Rack mounting the frame,•Module instal
26 Kameleon Frames Instruction ManualSection 2 — Installation Rack Mounting the FrameUse the rear support hardware to help support the weight of the f
Kameleon Frames Instruction Manual 27Rack Mounting the Frame GroundingThe 2000T3 frame provides a frame grounding post below the AC plug receptacles.
28 Kameleon Frames Instruction ManualSection 2 — Installation Power SuppliesThere are two types of 2000 Series power supplies — one for use in the 3 R
Kameleon Frames Instruction Manual 29Module Installation Figure 10. Power Supply Locking PinModule InstallationThere are twelve front slot and twelve
Kameleon Frames Instruction Manual 3 Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30 Kameleon Frames Instruction ManualSection 2 — Installation Rear ModulesWhen installing a front and rear media module pair, the rear module should b
Kameleon Frames Instruction Manual 31Module Installation Front ModulesFigure 13 illustrates a front media module installation.Figure 13. Typical 2000
32 Kameleon Frames Instruction ManualSection 2 — Installation Reference InputsThe 2000T3 frame’s Reference input (see Figure 14) uses loop-through con
Kameleon Frames Instruction Manual 33Module Installation Frame Health Alarm Connector (2000T3 only)The frame health alarm provides a relay closure tha
34 Kameleon Frames Instruction ManualSection 2 — Installation A number of frames can be coupled together as one alarm circuit. Refer to Figure 17 for
Kameleon Frames Instruction Manual 35 Section 3Power UpIntroductionThis section contains information about:• Power Connections•Applying PowerCAUTION V
36 Kameleon Frames Instruction ManualSection 3 — Power Up Power ConnectionsThe 2000 Series frames and optional redundant power supplies are shipped wi
Kameleon Frames Instruction Manual 37Power Connections Line Cord Retainer ClipTo help prevent accidental loss of power, the AC line cord is held in pl
38 Kameleon Frames Instruction ManualSection 3 — Power Up Applying PowerUpon applying power to the frame, verify that the green power LEDs for each po
Kameleon Frames Instruction Manual 39 Section 4SpeciÞcationsIntroductionThis section discusses specifications for the 2000 Series frames and the 2000PS
4Kameleon Frames Instruction ManualContents Reference Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40 Kameleon Frames Instruction ManualSection 4 — Specifications Operating ConditionsOperating temperature range 0 to 40 degrees CNon-operating temperat
Kameleon Frames Instruction Manual 41Power Supply Power SupplySee Table 5 for a list of power supply specifications. Specifications are subject to chang
42 Kameleon Frames Instruction ManualSection 4 — Specifications
Kameleon Frames Instruction Manual 43 Section 5ServiceIntroductionThis section contains general frame service information concerning:• Power supply mo
44 Kameleon Frames Instruction ManualSection 5 — Service Power SuppliesThe Grass Valley 2000 Series Power Supply sleds are designed to carry two 24V p
Kameleon Frames Instruction Manual 45Power Supplies Monitoring Power Supplies and FansIf the 2000NET Network Interface Module is installed, power supp
46 Kameleon Frames Instruction ManualSection 5 — Service Figure 24. Power Supply Voltage Testpoints3. Check Control Settings.If there is any question
Kameleon Frames Instruction Manual 47Fan Replacement Fan ReplacementA fan failure is reported through the 2000NET module (if present) to the Health Al
48 Kameleon Frames Instruction ManualSection 5 — Service MaintenanceEach of the 2000 Series frames has a filter located on the inside of the front cove
Kameleon Frames Instruction Manual 49 IndexNumerics2000GEN moduledescription 202000NET moduledescription 19AAC power 21, 22alarm 21alarm circuit
Kameleon Frames Instruction Manual 5 Preface About This Manual This manual provides installation, configuration, operation, and safety and regulator
50 Kameleon Frames Instruction ManualIndex Mmaintenance 48media module capacity 23NNetwork Interface Module 29Oonline documentation 2optionsframe
6Kameleon Frames Instruction ManualPreface
Kameleon Frames Instruction Manual 7 Regulatory Notices Certifications and Compliances FCC Emission Control This equipment has been tested and found
8Kameleon Frames Instruction ManualRegulatory Notices Canadian Certified Power Cords Canadian approval includes the products and power cords appropr
Kameleon Frames Instruction Manual 9Regulatory Notices FCC Emission Limits This device complies with Part 15 of the FCC Rules. Operation is subject