Grass-valley 8937 v.1.1.0 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Ausrüstung Grass-valley 8937 v.1.1.0 herunter. Grass Valley 8937 v.1.1.0 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - 8937/8937D

8937/8937DSDI/ASI RECLOCKING EQ SNMP DA MODULESInstruction ManualSOFTWARE VERSION 1.1.0071827003NOVEMBER 2008

Seite 2 - CERTIFICATE

10 8937/8937D — Instruction ManualInstallation InstallationThe 8937 and 8937D modules can be installed in either an 8900 Gecko or GeckoFlex frame. An

Seite 3

8937/8937D — Instruction Manual 11Installation The third slot from the right is allocated for either a Frame Monitor Module or a 8900NET (Net Card) Ne

Seite 4 - Contacting Grass Valley

12 8937/8937D — Instruction ManualInstallation GeckoFlex FrameInstallation of the 8937 and 8937D module in a GeckoFlex frame is a process of:1. Instal

Seite 5 - Contents

8937/8937D — Instruction Manual 13Installation Rear Module InstallationTo install a rear module into the frame, follow these steps:Note Please read Mo

Seite 6

14 8937/8937D — Instruction ManualInstallation Front Module InstallationAfter installing the rear module, install the front module as follows:Note If

Seite 7 - About This Manual

8937/8937D — Instruction Manual 15Installation Cabling8937 ModuleRefer to Figure 5 for cabling the 8937 module. Cabling to and from the module is done

Seite 8

16 8937/8937D — Instruction ManualInstallation 8737D ModuleRefer to Figure 6 for cabling the 8937D module. Cabling to and from the module is done at t

Seite 9 - Reclocking EQ SNMP DAs

8937/8937D — Instruction Manual 17Power Up Power UpThe front LED indicators and configuration switches are illustrated for the 8937 in Figure 7. The f

Seite 10 - Installation

18 8937/8937D — Instruction ManualPower Up Operation Indicator LEDsRefer to Figure 7 on page 17 (8937) and Figure 8 on page 17 (8937D) and Table 2 for

Seite 11 - 8270_02r1

8937/8937D — Instruction Manual 19Power Up Table 3 gives an overall summary of the LED indicator and reported input signal state for all possible mode

Seite 12 - GeckoFlex Frame

Affiliate with the N.V. KEMA in The Netherlands CERTIFICATECertificate Number: 510040.001 The Quality System of: Grass Valley, Inc. 400 Providence Min

Seite 13 - Rear Module Installation

20 8937/8937D — Instruction ManualConfiguration ConfigurationConfiguration and monitoring can be performed using local jumper con-trols, a web browser

Seite 14 - Front Module Installation

8937/8937D — Instruction Manual 21Configuration Configuration SummaryThe configuration parameters and monitoring functions available with the local on

Seite 15 - 8937 Module

22 8937/8937D — Instruction ManualConfiguration Local On-Board Configuration8937 ModuleTwo on-board jumpers are present on the 8937 module to configur

Seite 16 - Looping Capabilities

8937/8937D — Instruction Manual 23Configuration 8937D ModuleThree onboard jumpers are present on the 8937D to configure module for-matting. Refer to F

Seite 17 - Power Up

24 8937/8937D — Instruction ManualConfiguration Remote Configuration and Monitoring8937/8937D configuration and monitoring can be performed using a we

Seite 18 - Operation Indicator LEDs

8937/8937D — Instruction Manual 25Configuration An example of the Newton Configurator is shown in Figure 11. Figure 11. Newton Configurator ExampleWe

Seite 19

26 8937/8937D — Instruction ManualConfiguration Note The physical appearance of the graphics on the web pages shown in this manual represent the use o

Seite 20 - Configuration

8937/8937D — Instruction Manual 27Configuration 8937 and 8937D Links and Web PagesThe 8900 GUI provides the following links and web pages for the 8937

Seite 21 - Configuration Summary

28 8937/8937D — Instruction ManualConfiguration Status Web PageThe Status web page (Figure 14 on page 29 for 8937 and Figure 15 on page 29Usethislink

Seite 22 - Local On-Board Configuration

8937/8937D — Instruction Manual 29Configuration Figure 14. 8937 Status Web PageFigure 15. 8937D Status Web Page

Seite 23 - 8937D Module

8937/8937DSDI/ASI RECLOCKING EQ SNMP DA MODULESInstruction ManualSOFTWARE VERSION 1.1.0071827003NOVEMBER 2008

Seite 24 - 8900NET Module Information

30 8937/8937D — Instruction ManualConfiguration Standard Selections Web PageUsethislinkThe Standard Selections web page allows you to set loss of sign

Seite 25 - Web Browser Interface

8937/8937D — Instruction Manual 31Configuration When Manual mode is selected in the Mode 1 pulldown and the Apply button is selected, a Standard Selec

Seite 26 - 8270_11r0

32 8937/8937D — Instruction ManualConfiguration 8937D ModuleThe Standard Selections page for the 8937D (Figure 18 on page 33) provides separate contro

Seite 27

8937/8937D — Instruction Manual 33Configuration Note In Manual mode, if the input signal does not match the selected standard, Signal Not Present will

Seite 28 - Status Web Page

34 8937/8937D — Instruction ManualConfiguration Recall Factory Defaults Web PageUsethislinkUse the Recall Factory Defaults web page (Figure 19) to rec

Seite 29

8937/8937D — Instruction Manual 35Configuration Slot Config Web PageUsethislinkUse the Slot Config web page (Figure 20 on page 36) to perform the fol-

Seite 30 - Standard Selections Web Page

36 8937/8937D — Instruction ManualConfiguration Figure 20. Slot Config Web PageFrame Health ReportingProvides a link to the Frame Health Reports web

Seite 31

8937/8937D — Instruction Manual 37Configuration SNMP Trap ReportsSelect the SNMP Trap Reports link to open the 8900NET SNMP Reporting web page. this l

Seite 32

38 8937/8937D — Instruction ManualSoftware Updating Software UpdatingIf a software update becomes available for this module, the software upgrade proc

Seite 33

8937/8937D — Instruction Manual 39Status Monitoring External Frame AlarmAn external Frame Alarm output is available on pins 8 and 9 of the RS-232 conn

Seite 34

4 8937/8937D — Instruction Manual Contacting Grass ValleyCopyright © Thomson. All rights reserved.This product may be covered by one or more U.S. an

Seite 35 - Slot Config Web Page

40 8937/8937D — Instruction ManualStatus Monitoring Web Browser Interface The 8900NET module controls a web browser GUI that indicates frame and modul

Seite 36 - LED Reports

8937/8937D — Instruction Manual 41Specifications SpecificationsTable 7. 8937 and 8937D SpecificationsParameter ValueSerial Digital Component InputsNu

Seite 37 - SNMP Trap Reports

42 8937/8937D — Instruction ManualService ServiceThe 8937 and 8937D modules make extensive use of surface-mount tech-nology and programmed parts to ac

Seite 38 - Status Monitoring

8937/8937D — Instruction Manual 43Functional Description Functional DescriptionInput and Output ProcessingThe input section(s) receive SD (standard de

Seite 39 - LED Reporting

44 8937/8937D — Instruction ManualFunctional Description

Seite 40 - SNMP Reporting

8937/8937D — Instruction Manual 45 IndexNumerics143 Mb LED 18, 19177 Mb LED 18, 19270 Mb LED 18, 19360 Mb LED 18, 198900A-R rear module (GeckoFl

Seite 41 - Specifications

46 8937/8937D — Instruction ManualIndex graphical user interface (GUI) 27Grass Valley web site 4Iinput status summary 19inputscabling (8937) 15c

Seite 42 - Test Points

8937/8937D — Instruction Manual 47Index Ttestpoints 42troubleshooting 42Vvoltage tespoints 42Wweb browseroverview 25web sitedocumentation 4FAQ

Seite 43 - Functional Description

48 8937/8937D — Instruction ManualIndex

Seite 44

8937/8937D — Instruction Manual 5 ContentsPreface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 45

6 8937/8937D — Instruction ManualContents Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 46

8937/8937D — Instruction Manual 7 PrefaceAbout This ManualThis manual describes the features of the 8937 and 8937D modules in the GeckoFlex Signal P

Seite 47

8 8937/8937D — Instruction ManualPreface

Seite 48

8937/8937D — Instruction Manual 9 8937 and 8937D SDI/ASI Reclocking EQ SNMP DAs IntroductionThe 8937 module is a 1 x 8 looping input, auto-reclocking,